SORENSEN DHP-30-330

0 - 30 VDC  0 - 330 AMPS

$1695

Available in our eBay Store

OR

SOLD

This supply is basically new, it was used once for a short time and then de-installed

so we are listing it as used.

The DHP family provides models ranging in output power from 5 kW to 20 kW in a single chassis. Programmable output voltages range from 5V to 400 VDC, delivering up to 3,000 amperes. This family has two operational modes, constant-voltage and constant-current.

The DHP family uses control technology that allows 9 auto sequence steps, each step can be up to 99,999 seconds in duration. Combining all the steps allows a maximum auto-step program 27.7 hours long. Various voltages, currents and durations can be programmed for each step.

This family has standard analog and a variety of combinations of IEEE-488.2, RS 232 and/or isolated analog input control interface options.

All models come with the standard Sorensen 5-year warranty and CE Mark

This equipment will ship freight secured to a pallet. We will protect it with heavy covering.

[Click on Photos for Larger Image]

Specifications

Common
Operating Temperature 0°C to +50°C, no derating
Storage Temperature -20°C to 70°C
Cooling Internal fan
Front Panel Controls Keypad to select/adjust voltage, current and power with non-volatile memories to store commonly used parameters
Displays and Indicators Back lit LCD alphanumeric display and LEDs
Built-in Protection Overtemperature, brown out, turn on surge limit, slow start, overvoltage (OVP resettable without recycling power)
Remote Sense The maximum line drop is 3% per line or 1V for 5-15V units, 3V for all others. Line drop subtracts from the maximum available output voltage at full rated power.
Remote Control/Monitor (Rear Panel) On/off control via contact closure, 6-120 VDC, 12-240 VAC, TTL or CMOS switch, output voltage and current monitor, (0-10 volt) OVP limit set, summary fault status
Internal Programming 9 memories are on-board for auto-step programming. Each step can be 1 second to 99,999 seconds or 27.78 hours long.
Input
Voltage and Frequency 190-253 VAC, 47-63 Hz (Standard)
360-440 VAC, 47-63 Hz (Option)
432-528 VAC, 47-63 Hz (Option)

Three phase, 3-wire plus ground, Delta or Wye
input may be used (Wye does not require the
neutral connection)
Power Factor 0.72 min.
Output
Voltage, Current,
and Ripple
0-30 vdc 0-330  amps 10 mV ripple
Regulation
(Line or Load )
Voltage: 0.1% of maximum rated output
Current: 0.5% of maximum rated output
Line: For input voltage variation over the AC input voltage range, with constant rated load.
Load: For 0-100% load variation, with constant nominal line voltage.
Transient Response 2 ms to steady state output voltage (within 2% of Vmax) for 30% step load change
Stability ±0.05% maximum rating per 8 hours after a 30 minute warm-up time at fixed line, load and temperature
Efficiency 80% minimum at full load
Temperature Coefficient 0.02%/°C of rated output voltage; 0.03%/°C of rated output current. Change in output per °C change in ambient temperature, with constant line and load.
Remote Digital Control
Programming Resolution Voltage: 0.3% of full scale;
Current: 0.3% of full scale;
Overvoltage Protection: 0.5% of full scale (full scale is 110% of maximum output voltage)
Programming Accuracy Voltage: 0.1% + 0.3% of maximum output voltage;
Current: 0.3% + 0.3% of maximum output current*;
Overvoltage Protection: 0.5% + 0.5% of maximum output voltage
Readback Resolution Voltage and Current: 0.3% of full scale
Readback Accuracy Voltage: 0.1% + 0.3% of full scale output voltage;
Current: 0.3% + 0.3% of full scale output current*
Soft Calibration Calibration via front panel without removing chassis covers
Software LabVIEW® driver for M9D
Regulatory Compliance CE mark, UL(Up to 10kW output), cUL (Up to 10kW output)
Dimensions
Case 1 3U - 5-1/4” (133 mm) H
19” (482 mm) W
22” (558 mm) D
Weight & Shipping Weight
Weight: Maximum Case I: 80 lbs. (55 kg)
Shipping Weight: Maximum Case I:120 lbs. (73 kg)

 